| Hasco
Component's electromechanical relays range from less than
an amp to 80 amps. Hasco's relays are UL and CSA with some
TUV ratings. All relays have DC coils and many have an
AC coil. They come sealed for wave soldering and washing
thereby allowing the relays to be put on any assemble line.
There are surface mount low current relays available as
well.
KLT1C12DC12-L LATCHING RELAY
| FEATURES |
|
Highly reliable, Low cost |
 |
Miniature size & Large switch capacity up to 20A |
 |
Highly dielectric strength type |
 |
Fully Sealed |
 |
Inexpensive |
|
PATENT PENDING |
| ELECTRICAL RATINGS |
| 3 Amp: |
3A at 120VAC or 28VDC resistive |
 |
| 6 Amp: |
6A at 120VDC or 28VDC;6A at 240VAC general purpose;
1/4 hp at 120VAC |
 |
| 12 & 15 Amp: |
12A at 120VAC or 28VDC; 12A at 240VAC general
purpose; 7A at 277VAC general purpose; 1/4 hp at 120VAC;
15A at 120VAC resistive; 20A,120VAC general purpose |
| |
Pilot duty: |
40A in-rush, 4A steady state at 125VAC |
| |
|
10A in-rush, 1A steady state at 240VAC |
|
 |
| N.O. only, Single Pole: |
10A at 12VDC Tungsten; 15A at 120VAC Tungsten |
| |
1/2 hp at 120VAC; 5.4A at 277 VAC Ballast |
| GENERAL DATA |
| Contact resistance: |
50mOhms Max. |
 |
| Operate Time: |
8ms Max. (at nominal voltage) |
 |
| Operate Bounce Time: |
3 ms Max. |
 |
| Release Time: |
5 ms Max. |
 |
| Release Bounce Time:
|
8 ms Max |
 |
| Max. Switching Voltage: |
277VAC & 125VDC |
 |
| Min. Permissible Load
(reference value): |
3 Amp: 5VDC at 1mA |
| |
6, 12, 15 & 20 Amp: 5VDC at 100mA |
 |
| Insulation Rating: |
Class B & Class F |
 |
| Insulation Resistance:
|
more than 100Ohms at 500VDC |
 |
| Dielectric Strength: |
750VAC (50/60Hz), between open contacts |
| |
1500VAC (50/60Hz), between coil & contact |
 |
| Vibration: |
1.5mm double amplitude, 10 to 50Hz |
 |
| Shock: |
100 m/sec2 (approx. 10G’s) |
 |
| Operation Frequency: |
Mechanical: |
18,000 operations/hour |
| Electrical: |
1,800 operations/hour (under rated
load) |
 |
| Service Life: |
Mechanical: |
10 million operations |
| Electrical: |
100,000 operations min. at rated resistive load |
 |
| Temperature Range: |
Class B: |
– 40°C to 85°C |
| Class F: |
–40°C to 105°C |
 |
| Temperature Rise: |
Less than 35 degrees |
 |
| Humidity: |
45% - 85% RH |
 |
| Approximate Weight: |
12 grams |
| COIL RATINGS |
|
Nominal
Voltage
(VDC) |
Set/Reset
Voltage
(VDC) |
Resistance
+/-10% @250C
(Ohms) |
|
5 |
4 |
27 |
|
6 |
4.8 |
40 |
|
9 |
7.2 |
97 |
|
12 |
9.6 |
155 |
|
24 |
19.2 |
660 |
|
48 |
38.4 |
2560 |
| REMARK |
Use alcohol, freon or water for cleaning (water temperature not to exceed 500C |
ORDERING INFORMATION

|
DIMENSIONS: mm (inch)
NOTE: RELAYS ARE SHIPPED IN THE “RESET STATE”. However, shock may cause this state to change. Therefore,
it is necessary to confirm the relay’s state BEFORE IT’S USE.
|