Electromechanical Relays

Hasco Component's electromechanical relays range from less than an amp to 80 amps. Hasco's relays are UL and CSA with some TUV ratings. All relays have DC coils and many have an AC coil. They come sealed for wave soldering and washing thereby allowing the relays to be put on any assemble line. There are surface mount low current relays available as well.

DPDT PC 150 MW POWER CONSUMPTION

SMALL SIZED POLARIZED RELAY BEING CAPABLE FOR WIDE USE

FEATURES
High sensitive 2 pole relay suitable for signal circuit DPDT PC 150 MW Power Consumption - HAS & HS Series
Ultra-high sensitive type 150mW
High sensitive type 200mW. Standard type 400mW
Latching type relay provided with memory function
is available too
Adopts twin contacts that are superior in contact reliability
Gold-clad Silver palladium contact available too
Completely enclosed type relay with sealed construction being superior in durability to the environment
UL File No. 75887
CSA File No. 180958 (LR93742)
BABT Certificate No. 609662
 
APPLICATIONS
Switch board. Facsimile. Telephones
Audio equipment. Industrial machines

CONTACT RATING
Contact arrangement DPDT (2C)
Contact Material Ag + Au clad or AgPd + Au Clad
Initial contact resistance max. Max. 50mOhms
Contacting
(Resistive load)
Max. switching voltage 220V DC    250V AC.
Max. switching current 2A
Max. switching power 60W (DC)    125VA (AC)
Max. carry current 2A
Rated contact load 2A 30VDC   1A 125VAC

GENERAL DATA
Life expectancy Mechanical Life 100,000,000 Operations (at 600cpm)
300,000,000 Operations (2A 30VDC) (at 20cpm)
Electrical Life 1,000,000 Operations (1A 30VDC) (at 20cpm)
Operate/Release time Operate time (Set/Reset time)
Max. 5 msec.
Release time Max. 3.5 msec.
Temperature Characteristics Coil Temp. Rise Standard Less than 40°C (at nominal coil voltage)
Sensitive Less than 30°C (at nominal coil voltage)
Operate ambient temp. -40°C to +70°C (Without being frozen)
Storage ambient temp. -40°C to +80°C (Without being frozen)
Initial breakdown voltage Between coil and contacts 1,500Vrms (1 minute)
Between open contacts 1,000Vrms (1 minute)
Initial insulation resistance   Min. 100M Ohms (at 500V DC)
Environmental requirement Ambient humidity Max. 85% RH
Vibration resistance Vibration (Malfunction) 10 ~55Hz at double amplitude of 1.5mm
Shock resistance Mechanical damage Min. 980m/s2 (100G)
Malfunction Min. 342m/s2 (40G)

ORDERING INFORMATION
HAS112 (standard)
HS212 (sensitive)
NIL: Single side stable
L: 2 coil latching K: 1 coil latching
Coil Voltage
5, 6, 9, 12, 24, 48

COIL RATING Single Side Stable at 120°C *1.5 & 3V Available
Relay
Code
Nominal
Voltage
Coil
Resistance
(W) ±10%
Nominal
Current
(mA)
Pick-Up
Voltage
Drop-Out
Voltage
Max.
Allowable
Voltage
Nominal
Power
(mW)
HAS-112-5
5
62.5
80
70% of
Nominal
Voltage
10% of
Nominal
Voltage
150% of
Nominal
Voltage
Approx.
400mW
HAS-112-6
6
90
60
HAS-112-9
9
203
40
HAS-112-12
12
360
30
HAS-112-24
24
1440
10
HAS-112-48
48
5760
8

COIL RATING 1 Coil Latching at 20°C
Relay
Code
Nominal
Voltage
Coil
Resistance
(W) ±10%
Nominal
Current
(mA)
Pick-Up
Voltage
Max.
Allowable
Voltage
Nominal
Power
(mW)
HAS-112K-5
5
69.4
72
70% of
Nominal
Voltage
150% of
Nominal
Voltage
Approx.
360mW
HAS-112K-6
6
100
60
HAS-112K-9
9
225
40
HAS-112K-12
12
400
30
HAS-112K-24
24
1600
15
HAS-112K-48
48
6400
7.5

COIL RATING 2 Coil Latching at 20°C
Relay
Code
Nominal
Voltage
Coil
Resistance
(W) ±10%
Nominal
Current
(mA)
Pick-Up
Voltage
Max.
Allowable
Voltage
Nominal
Power
(mW)
HAS-112L-5
5
69.4
72
70% of
Nominal
Voltage
150% of
Nominal
Voltage
Approx.
360mW
HAS-112L-6
6
100
60
HAS-112L-9
9
225
40
HAS-112L-12
12
400
30
HAS-112L-24
24
1600
15
HAS-112L-48
48
6400
7.5

COIL RATING Single Stable at 20°C
Relay
Code
Nominal
Voltage
Coil
Resistance
(W) ±10%
Nominal
Current
(mA)
Pick-Up
Voltage
Drop-Out
Voltage
Max.
Allowable
Voltage
Nominal
Power
(mW)
HS-212-5
5
167
29
80% of
Nominal
Voltage
10% of
Nominal
Voltage
230% of
Nominal
Voltage
Approx.
150mW
HS-212-6
6
240
25
HS-212-9
9
540
16.6
HS-212-12
12
960
12.5
HS-212-24
24
3840
6
HS-212-48
48
15360
3

COIL RATING 1 Coil Latching at 20°C
Relay
Code
Nominal
Voltage
Coil
Resistance
(W) ±10%
Nominal
Current
(mA)
Pick-Up
Voltage
Max.
Allowable
Voltage
Nominal
Power
(mW)
HS-212K-5
5
139
35.9
70% of
Nominal
Voltage
200% of
Nominal
Voltage
Approx.
180mW
HS-212K-6
6
200
30
HS-212K-9
9
450
20
HS-212K-12
12
800
15
HS-212K-24
24
3200
7.5
HS-212K-48
48
12800
3.7

COIL RATING 2 Coil Latching at 20°C
Relay
Code
Nominal
Voltage
Coil
Resistance
(W) ±10%
Nominal
Current
(mA)
Pick-Up
Voltage
Max.
Allowable
Voltage
Nominal
Power
(mW)
HS-212L-5
5
139
35.9
70% of
Nominal
Voltage
200% of
Nominal
Voltage
Approx.
180mW
HS-212L-6
6
200
30
HS-212L-9
9
450
20
HS-212L-12
12
800
15
HS-212L-24
24
3200
7.5
HS-212L-48
48
12800
3.7

DIMENSIONS
Dimensions and Schematics

GRAPHS
Graph: Mechanical life test
Graph: Mechanical life test
Graph: Electrical life test (2A 30VDC resistive load)
Graph: Electrical life test (2A 30VDC resistive load)
Graph: Contact reliability test (DC 10V-10mA, 300cpm, 70°C
Graph: Contact reliability test (DC 10V-10mA, 300cpm, 70°C

PART NUMBERS
HAS112DC5 HAS112KDC5-P HS212KDC5-P
HAS112DC6
HAS112KDC6-P HS212KDC6-P
HAS112DC9 HAS112KDC9-P HS212KDC9-P
HAS112DC12 HAS112KDC12-P HS212KDC12-P
HAS112DC24 HAS112KDC24-P HS212KDC24-P
HAS112DC48 HAS112KDC48-P HS212KDC48-P
HS212DC5 HAS112LDC5-P HS212LDC5-P
HS212DC6 HAS112LDC6-P HS212LDC6-P
HS212DC9 HAS112LDC9-P HS212LDC9-P
HS212DC12 HAS112LDC12-P HS212LDC12-P
HS212DC24 HAS112LDC24-P HS212LDC24-P
HS212DC48 HAS112LDC48-P HS212LDC48-P
HS212DC48B HS212DC5-P  
HAS112DC5-P HS212DC6-P  
HAS112DC6-P HS212DC9-P  
HAS112DC9-P HS212DC12-P  
HAS112DC12-P HS212DC24-P  
HAS112DC24-P HS212DC48-P  
HAS112DC48-P    

E-mail This Page
  Print Preview

 
Hasco Components International Corp.: A complete source for Reed Swiches, Electromechanical Relays and Magnets since 1976 - 906 Jericho Turnpike - New Hyde Park, NY  11040 - Phone: 516-328-9292 - Fax: 516-326-9125
© 2008 Hasco Components Int'l Corp.