HPK Series
SPDT 35 Amp
Features
- 25A, 32A or 35A switching capability
- Surge voltage up to 6kV (between coil and contacts)
- 1 Form C and 1 Form A configurations available
- Dust Cover Type, Flux Free Type and Sealed Type is available
- Creepage Distance up to 6mm
- Outline Dimensions: 21.6mm×16.0mm×20.6mm
![]() |
![]() |
![]() |
Contact Ratings
Contact Arrangement | 1A, 1B, 1C |
Contact Resistance | 100mΩ (1A 24VDC) |
Contact Material | AgSnO alloy |
Contact Rating(Resistive) | NO:35A/277VAC NC:16A/277VAC |
Max. Switching Voltage | 277VAC |
Max. Switching Current | 35A |
Max. Switching Power | 9695VA |
Mechanical Life | 1×105 operations(frequency 9,000 operations/hr) |
Electrical Life | See more details at "safety approval ratings" |
Ordering Information
Characteristics
Insulation Resistance | 100MΩ (at 500VDC) | |
Dielectric |
Between coil & contacts | 4000VAC 1min |
Between open contacts | 1500VAC 1min | |
Operate time (at nomi. volt.) | ≤15ms | |
Release time (at nomi. volt.) | ≤10ms | |
Humidity | 85% (20°C) | |
Storage Condition | -40°C~+85°C | |
Operating Condition | Class F: -40°C~+60°C Class H: -40°C~+85°C -40°C~+105°C(at 25A) |
|
Class F/H | Insulation System Class F/H | |
Shock Resistance |
Operating extremes | 10G |
Damage limits | 100G | |
Vibration resistance | 10Hz ~ 50Hz 1.0mm DA | |
Unit weight | Approx. 15g | |
Construction | Sealed Type, Dust Cover Type, Flux Free Type |
Notes:
1) The data shown above are initial values.
2) Please find coil temperature curve in the characteristic curved below.
Coil Data at 25°C
Standard Type
Nominal |
Pick-up |
Drop-out |
Holding |
Coil |
---|---|---|---|---|
6 | 4.8 | 0.30 | 1.92~2.16 | 22 |
9 | 7.2 | 0.45 | 2.88~3.24 | 49 |
12 | 9.6 | 0.60 | 3.84~4.32 | 86 |
24 | 19.2 | 1.20 | 7.68~8.64 | 345 |
48 | 38.4 | 2.40 | 15.36~17.28 | 1380 |
Coil
Power consumption at rated voltage | 1670mW |
Power consumption at holding voltage | 190mW(2) |
Notes:
(1) To energize relay properly apply 100%~120% nominal coil voltage for 200ms.
(2) Coil holding voltage is 32~36% of nominal voltage after applying nominal voltage for 200ms.
Safety Approval Ratings
UL&CUL |
NO:35A/277VAC, 70°C, 5×104 OPS |
|
TüV |
PENDING |
NO:35A/277VAC NC:16A/277VAC |
Outline Dimensions, Wiring Diagram And PC Board Layout Unit: inch(mm)
Outline Dimensions |
---|
![]() |
Wiring Diagram (Bottom view) |
![]() |
PCB Layout (Bottom view) |
![]() |
Remark:
1) In case of no tolerance shown in outline dimension: outline dimension ≤1mm,tolerance should be ±0.2mm; outline dimension >1mm and ≤5mm,tolerance should be ±0.3mm;outline dimension >5mm, tolerance should be ±0.4mm.
2) The tolerance without indicating for PCB layout is always ±0.1mm.
Characteristic Curves
![]() |
![]() |